Regulated laboratory architecture

The laboratory VLAN is not an extension of the office LAN

Flat networks are how an office phishing email reaches a chromatography data system. We design segmented laboratory networks with deny-by-default policies between zones, built around what your instruments and applications actually require.

Laboratory analyst working with connected instruments

Segmentation as a minimum, not an aspiration

A laboratory that shares one flat network between reception PCs, guest Wi-Fi, CCTV and a GC-MS workstation has no meaningful boundary to defend. Segmentation gives each class of system its own zone, and makes every crossing between zones an explicit, documented decision rather than an accident of cabling.

The design below is a typical starting structure. The final scheme depends on your instrument map, application dependencies and what the instrument vendors support.

Typical layout

Minimum logical segmentation

Corporate endpoints

Office laptops and desktops. General productivity and internet access.

GxP and laboratory users

Laboratory staff workstations that handle regulated records but are not instrument-attached.

Scientific instruments

Instrument workstations and embedded controllers. The most tightly restricted zone.

Servers

CDS, LIMS, file, application and database services.

Voice

IP telephony, kept off the data zones.

Guest Wi-Fi

Visitor access with no route to any internal zone.

CCTV and IoT

Cameras, recorders and connected building devices, which are rarely patched and should never be adjacent to scientific data.

Building and environmental systems

HVAC, environmental monitoring and facility controllers.

Backup and IT management

Backup infrastructure and administrative access, isolated so that ransomware reaching a user zone does not reach the backups.

What the engagement delivers

  • Site and network assessment against your instrument and application map
  • VLAN and security-zone design with an IP addressing and subnet plan
  • Deny-by-default inter-VLAN policy, with each permitted flow documented and justified
  • Managed switch and firewall configuration, including PoE where cameras and access points need it
  • Separate corporate and guest wireless with no route between them
  • Network device hardening and secure administrative access
  • Configuration backups for every firewall and switch
  • Network topology and data-flow diagrams, and an IP and VLAN register

How a segmentation project runs

  1. Discover

    Map every connected device, what it talks to, and which vendor supports it. Nothing is segmented before it is understood.

  2. Design

    Zones, addressing, and the permitted flows between them, agreed with the laboratory and with instrument vendors where their software is affected.

  3. Stage

    Build and test the configuration out of hours, with a documented rollback for each change.

  4. Cut over

    Move zone by zone, verifying instrument and application behaviour after each step rather than at the end.

  5. Document

    Topology, VLAN register, firewall rule records and the justification for every inter-zone rule.

Common questions

Will segmentation break our instrument software?

It can, if it is done without mapping dependencies first, which is why discovery comes before design. An HPLC workstation normally needs to reach its scientific application and database services, DNS and NTP, and specifically approved infrastructure — and nothing else. We establish that list with you and the vendor before any policy is enforced, and verify instrument behaviour after each cutover step.

How many VLANs do we actually need?

Fewer than the list above if you are small, more if you have multiple buildings or a wide instrument estate. The useful question is not the count but whether any two systems with very different risk profiles share a zone. Instruments, backups and guest access should always be separated.

Can you work with our existing switches and firewall?

Usually. We assess what you have against the design before recommending replacement. Where existing equipment supports the required VLANs and policies, reusing it is normally the right call.

Where our responsibility ends

Pracoda provides technical infrastructure implementation and documentation support. Regulatory interpretation, GxP applicability decisions, validation approval, SOP approval, data review and final quality release remain with the client's authorized QA, system owner or qualified regulatory and validation specialists. Instrument software and scientific equipment support remain subject to the instrument vendor's terms.

Talk to us about your laboratory network

Tell us roughly how many instruments and users you have and what the current network looks like. We will tell you what we would separate first.

  • Reply within one working day
  • Vendor compatibility checked before anything changes

We use your details only to reply to you. See our privacy policy.

Need a consultation?

Tell us what you are building.

Share the problem, the platform and the deadline. We will come back with an approach, a team and an estimate.